UL 60335-2-24 Integrated Door Endurance Test Machine For Refrigerator/ Microwave Oven
Product information:
Standard: IEC 60335-2-25 clause 18, IEC60335-2-24:2017, etc.
Application:
1. The device is used for mechanical endurance test to door system includes a hinge structure , microwave seals and other related components of microwave ovens, ovens, refrigerators and freezers, etc.
2. The device is used for durability test of the interlocking device of the doors, also can be used to assist other tests for door repeated opening and closing operations, such as during refrigerator defrost test and refrigerant leakage test.
Test sample:
1.Microwave ovens, ovens
2. Refrigeration appliances (refrigerators and freezers).
Feature: The equipment adopts PLC and servo motor control, with all stainless steel mechanical arms, vacuum suction structure, standard TFT true color LCD touch screen, can preset test angle and speed, simulated a human hand to open and close the door of microwave ovens and similar equipment, achieve intelligent control. The machine frame is made of high grade aluminum alloy profile, and the mechanical arms are installed on the columns, can satisfy left open and upper open door endurance test of different size. The power supply socket has the function of detecting, which can judge whether the test sample is electrified; during load test, if the test sample is not electrified during the test, the equipment will be automatically shut down. This feature can be enabled on the demands.
Structure: The equipment combines of electrical control cabinet (including load voltage regulating device), frame and mechanical arms.
Equipment dimensions: approx.: (W*D*H) 2500 * 1300 * 2000 (mm)
Equipment weight: 350kg
Parameters:
Power Supply | AC220V±10%/ 60 Hz, power 3KW |
Test Station |
3 station One station for opening and closing doors left and right, one station for flipping doors, and one station for opening and closing drawers |
Control Mode | PLC intelligent integrated control, 7-inch humanized touch interface operation |
Drive Mode | Servo motor drive |
Available Sample Type |
Allowable sample size range: Left and right door open/close station (middle): WDH≤1910×928×2035mm (Samples with 2 vertical doors at the same side or 1 door shown as following) 2. Flip door open/close station (right side): WDH≤1100×600×1000mm 3. Drawer open/close station (right side): drawer stroke ≤ 500mm
|
Clamping Method for Door | Vacuum suction cup, pneumatic |
Refrigerator/oven left and right door open/close station | |
Door opening and closing mechanism | Two sets, 1 set for opening and closing the upper door and 1 set for opening and closing the lower door, individually operation, no interference |
Column 1 | 2m height, the built-in screw guide adjustable mechanism can adjust the position of the upper and lower door opening mechanical arm to match different refrigerator door heights |
Open/close angle | 0-90°, can be preset |
Open/close direction | Left or right |
Open/close cycles | 0-999999 cycles, can be preset |
Open/close speed | 6-18 cycles /min |
Oven/microwave oven flip door open/close station | |
Open/close mechanical arm | 1 set |
Column 2 | 1.2m height, the adjustable mechanism of screw guide rail can adjust the position of flip cover manipulator to match the height of different sample covers |
Open/close angle | 0-90°, can be preset |
Open/close direction | Flip hinge up |
Open/close cycles | 0-999999 cycles, can be preset |
Open/close speed | 6-18 cycles/min |
Drawer open/close station | |
Drawer open/close mechanical arm | 1 set |
Column 3 | 1.2m height, the adjustable screw guide rail mechanism can adjust drawer manipulator position to match different sample cover heights |
Open/close stroke | 0-500mm, can be preset |
Open/close direction | Along the front and rear directions of the drawer rails |
Open/close cycles | 0-999999 cycles, can be preset |
Open/close speed | 6-18 cycles/min |
Left or Right Door/Dlip Door/Drawer Open and Close Method | The Vacuum suction cup sucks on the door tightly, then servo motor drives the door opening and closing mechanism back and forth, the door opening and closing frequency, door opening and closing angle, test cycles can be set and displayed on the touch screen |
Sample fixture | One left set and one right set |
Auxiliary unlocking mechanism | One set, configurated on flip door open/close station |
Load Voltage | 0-250V, adjustable |
Safety Protection | |
Power | Leakage protection, overload and short circuit protection |
Motor | Overload, short circuit protection |
![]() |
MOQ: | 1 |
Price: | Customized |
Standard Packaging: | Plywood Case |
Delivery Period: | 30 days |
Payment Method: | T/T |
Supply Capacity: | 5 sets per month |
UL 60335-2-24 Integrated Door Endurance Test Machine For Refrigerator/ Microwave Oven
Product information:
Standard: IEC 60335-2-25 clause 18, IEC60335-2-24:2017, etc.
Application:
1. The device is used for mechanical endurance test to door system includes a hinge structure , microwave seals and other related components of microwave ovens, ovens, refrigerators and freezers, etc.
2. The device is used for durability test of the interlocking device of the doors, also can be used to assist other tests for door repeated opening and closing operations, such as during refrigerator defrost test and refrigerant leakage test.
Test sample:
1.Microwave ovens, ovens
2. Refrigeration appliances (refrigerators and freezers).
Feature: The equipment adopts PLC and servo motor control, with all stainless steel mechanical arms, vacuum suction structure, standard TFT true color LCD touch screen, can preset test angle and speed, simulated a human hand to open and close the door of microwave ovens and similar equipment, achieve intelligent control. The machine frame is made of high grade aluminum alloy profile, and the mechanical arms are installed on the columns, can satisfy left open and upper open door endurance test of different size. The power supply socket has the function of detecting, which can judge whether the test sample is electrified; during load test, if the test sample is not electrified during the test, the equipment will be automatically shut down. This feature can be enabled on the demands.
Structure: The equipment combines of electrical control cabinet (including load voltage regulating device), frame and mechanical arms.
Equipment dimensions: approx.: (W*D*H) 2500 * 1300 * 2000 (mm)
Equipment weight: 350kg
Parameters:
Power Supply | AC220V±10%/ 60 Hz, power 3KW |
Test Station |
3 station One station for opening and closing doors left and right, one station for flipping doors, and one station for opening and closing drawers |
Control Mode | PLC intelligent integrated control, 7-inch humanized touch interface operation |
Drive Mode | Servo motor drive |
Available Sample Type |
Allowable sample size range: Left and right door open/close station (middle): WDH≤1910×928×2035mm (Samples with 2 vertical doors at the same side or 1 door shown as following) 2. Flip door open/close station (right side): WDH≤1100×600×1000mm 3. Drawer open/close station (right side): drawer stroke ≤ 500mm
|
Clamping Method for Door | Vacuum suction cup, pneumatic |
Refrigerator/oven left and right door open/close station | |
Door opening and closing mechanism | Two sets, 1 set for opening and closing the upper door and 1 set for opening and closing the lower door, individually operation, no interference |
Column 1 | 2m height, the built-in screw guide adjustable mechanism can adjust the position of the upper and lower door opening mechanical arm to match different refrigerator door heights |
Open/close angle | 0-90°, can be preset |
Open/close direction | Left or right |
Open/close cycles | 0-999999 cycles, can be preset |
Open/close speed | 6-18 cycles /min |
Oven/microwave oven flip door open/close station | |
Open/close mechanical arm | 1 set |
Column 2 | 1.2m height, the adjustable mechanism of screw guide rail can adjust the position of flip cover manipulator to match the height of different sample covers |
Open/close angle | 0-90°, can be preset |
Open/close direction | Flip hinge up |
Open/close cycles | 0-999999 cycles, can be preset |
Open/close speed | 6-18 cycles/min |
Drawer open/close station | |
Drawer open/close mechanical arm | 1 set |
Column 3 | 1.2m height, the adjustable screw guide rail mechanism can adjust drawer manipulator position to match different sample cover heights |
Open/close stroke | 0-500mm, can be preset |
Open/close direction | Along the front and rear directions of the drawer rails |
Open/close cycles | 0-999999 cycles, can be preset |
Open/close speed | 6-18 cycles/min |
Left or Right Door/Dlip Door/Drawer Open and Close Method | The Vacuum suction cup sucks on the door tightly, then servo motor drives the door opening and closing mechanism back and forth, the door opening and closing frequency, door opening and closing angle, test cycles can be set and displayed on the touch screen |
Sample fixture | One left set and one right set |
Auxiliary unlocking mechanism | One set, configurated on flip door open/close station |
Load Voltage | 0-250V, adjustable |
Safety Protection | |
Power | Leakage protection, overload and short circuit protection |
Motor | Overload, short circuit protection |