MOQ: | 1 |
Price: | Negotiable |
Standard Packaging: | Carton |
Delivery Period: | 25 Days |
Payment Method: | T/T |
Supply Capacity: | 30 sets per month |
IEC 60335-1 Clause 14 Impulse Test Generator Max. 12.5kV Transient Over Voltage Testing
Product Information:
Standard: Conform to IEC 60335-1 clause 14, etc.
Application: It is used to detect the transient over voltage of the components and the electrical clearance and the creepage distance.
Test sample: Household appliance, Audio, video and similar electronic apparatus.
Feature: The sample breakdown will produce a spark and acoustic, instrument peak voltage than the no-load voltage is decreased substantially (close to zero), when applying the same voltage in the next test, it will also show the above phenomenon.
Technical Parameters:
Model | SN1104 |
DC high voltage | Max. 12.5kV |
Impulse voltage wave |
Impulse wavefront time: 1.2 µs ± 30 %; Half value of after wave time: 50 µs ± 20 % Please note that the waveform should be checked on an external oscilloscope |
Instrument internal resistance |
2Ω,12Ω, 40Ω, 500Ω (Accuracy ± 10%) |
Peak voltage |
Low: 300 V~ 2,500V; High: 2,500 V~12,500V |
Impact interval time | 5 ~ 99s |
Impact cycles | 1 ~ 9999 |
Polarity | Positive and negative |
Working power source | Rated voltage: ~ 220V±10%, 50/60Hz |
Dimension | 430mm×180mm×480mm |
Weight | 30 KG |
MOQ: | 1 |
Price: | Negotiable |
Standard Packaging: | Carton |
Delivery Period: | 25 Days |
Payment Method: | T/T |
Supply Capacity: | 30 sets per month |
IEC 60335-1 Clause 14 Impulse Test Generator Max. 12.5kV Transient Over Voltage Testing
Product Information:
Standard: Conform to IEC 60335-1 clause 14, etc.
Application: It is used to detect the transient over voltage of the components and the electrical clearance and the creepage distance.
Test sample: Household appliance, Audio, video and similar electronic apparatus.
Feature: The sample breakdown will produce a spark and acoustic, instrument peak voltage than the no-load voltage is decreased substantially (close to zero), when applying the same voltage in the next test, it will also show the above phenomenon.
Technical Parameters:
Model | SN1104 |
DC high voltage | Max. 12.5kV |
Impulse voltage wave |
Impulse wavefront time: 1.2 µs ± 30 %; Half value of after wave time: 50 µs ± 20 % Please note that the waveform should be checked on an external oscilloscope |
Instrument internal resistance |
2Ω,12Ω, 40Ω, 500Ω (Accuracy ± 10%) |
Peak voltage |
Low: 300 V~ 2,500V; High: 2,500 V~12,500V |
Impact interval time | 5 ~ 99s |
Impact cycles | 1 ~ 9999 |
Polarity | Positive and negative |
Working power source | Rated voltage: ~ 220V±10%, 50/60Hz |
Dimension | 430mm×180mm×480mm |
Weight | 30 KG |