Send Message
products
PRODUCTS DETAILS
Home > Products >
High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate(Cost Additional )
Model Number
SN887B-100L
High-Temperature Range:
+60℃ ~ +180℃
Low-Temperature Range:
-10℃ ~ -70℃
Temperature Fluctuation:
±0.5℃
Temperature Deviation:
±2.0℃
Internal Dimensions:
W500*H500mm*D400mm
External Dimensions:
W1420mm*H1888mm*D1590mm
Product Volume:
100L
Product Weight:
Approximately 1200kg
Highlight:

IEC60068-2 Thermal Shock Test Chamber

,

High Performance Thermal Shock Test Chamber

,

Thermal Shock Test Chamber

Product Description

 

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

 

 

Product information:

 

This thermal shock test chamber meets the requirements of IEC60068-2-1, IEC60068-2-2, IEC60068-2-30 and IEC60068-2-78, and required by many standards.
It is used to verify whether there is a bad influence on the product due to rapid changes in high and low temperature in such a manner that the sample does not move.

 

Technical parameter:

 

Product Name Thermal Shock Test Chamber
Product Model SN887B-100L
Volume 100L
Internal Dimensions W500*H500mm*D400mm
External Dimensions W1420mm*H1888mm*D1590mm
Weight Approximately 1200kg
High-Temperature Range +60℃ ~ +180℃
Heating Time +20℃ ~ +180℃ ≤ 25 min
Note: The heating time refers to the performance when the high-temperature chamber operates independently.
Low-Temperature Range -10℃ ~ -70℃
Cooling Time +20℃ ~ -70℃ ≤ 60 min
Note: The cooling time refers to the performance when the low-temperature chamber operates independently.
Temperature Shock Range -40℃~150℃
Temperature Fluctuation ±0.5℃
Temperature Deviation ±2.0℃
Temperature Recovery Time ≤5min
Temperature Transition Time ≤10sec
Recovery Conditions

High-temperature exposure: +85℃ / 30 min → Ambient temperature exposure → Low-temperature exposure: -40℃ / 30 min

Maximum Sample Weight: 20 KG

 

 

Structural Features:

 

Standard Configuration of the Test Chamber

Flush-mounted handle.

Door Hinges: Imported SUS #304 stainless steel hinges.

Shelves: Two SUS #304 stainless steel grille-type shelves, with a maximum load of 20KG per layer.

Adjustable Shelf Tracks: Two sets with 40mm adjustable spacing.

Lead-through Port: One φ50mm port at the top of the chamber.

Chamber Door

Single Door: Opens outward, hinges on the left, handle on the right (when facing the front of the chamber).

Equipped with an observation window (W300 x H450mm) made of anti-fog tempered glass and Philips lighting.

Anti-condensation Heating Device: For window and door frames.

Additional Tempered Glass: Allows clear observation of tests inside the chamber.

Control Panel 7-inch display screen, over-temperature protection settings, SD card slot, and RS232 communication interface.
Mechanical Room Refrigeration unit, compressor water tray, and pressure relief device.
Power Distribution Control Cabinet Power distribution board, cooling fan, and main power switch.
Heater

Type: Finned tubular stainless steel electric heater.

Heating Control Method: SSR (Solid State Relay) with zero-crossing

point and periodic pulse width modulation.

Heating Power for Low-Temperature Zone: Approximately 6KW.

Heating Power for High-Temperature Zone: Approximately 9KW.

Power Cable Port and Drain Port Located at the back of the chamber.
Electrical Controller Model Custom seven-inch controller.
Operating Model Programmable operation / Chinese and English menu, touchscreen input.
Setting Range

High-temperature chamber preheating upper limit: +210℃

Low-temperature chamber pre-cooling lower limit: -80℃

Controller Specifications

Accuracy: Temperature ±0.1℃ + 1 digit

Resolution: Temperature ±0.01℃

Temperature slope: 0.1 ~ 9.9 (adjustable).

Includes upper and lower limit standby and alarm functions.

Temperature input signal: T-type armored thermocouple sensor.

6 sets of P.I.D. control parameters with automatic P.I.D. calculation

 

 

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2 0High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2 1

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2 2

 

products
PRODUCTS DETAILS
High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate(Cost Additional )
Model Number
SN887B-100L
High-Temperature Range:
+60℃ ~ +180℃
Low-Temperature Range:
-10℃ ~ -70℃
Temperature Fluctuation:
±0.5℃
Temperature Deviation:
±2.0℃
Internal Dimensions:
W500*H500mm*D400mm
External Dimensions:
W1420mm*H1888mm*D1590mm
Product Volume:
100L
Product Weight:
Approximately 1200kg
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 sets per month
Highlight

IEC60068-2 Thermal Shock Test Chamber

,

High Performance Thermal Shock Test Chamber

,

Thermal Shock Test Chamber

Product Description

 

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2

 

 

Product information:

 

This thermal shock test chamber meets the requirements of IEC60068-2-1, IEC60068-2-2, IEC60068-2-30 and IEC60068-2-78, and required by many standards.
It is used to verify whether there is a bad influence on the product due to rapid changes in high and low temperature in such a manner that the sample does not move.

 

Technical parameter:

 

Product Name Thermal Shock Test Chamber
Product Model SN887B-100L
Volume 100L
Internal Dimensions W500*H500mm*D400mm
External Dimensions W1420mm*H1888mm*D1590mm
Weight Approximately 1200kg
High-Temperature Range +60℃ ~ +180℃
Heating Time +20℃ ~ +180℃ ≤ 25 min
Note: The heating time refers to the performance when the high-temperature chamber operates independently.
Low-Temperature Range -10℃ ~ -70℃
Cooling Time +20℃ ~ -70℃ ≤ 60 min
Note: The cooling time refers to the performance when the low-temperature chamber operates independently.
Temperature Shock Range -40℃~150℃
Temperature Fluctuation ±0.5℃
Temperature Deviation ±2.0℃
Temperature Recovery Time ≤5min
Temperature Transition Time ≤10sec
Recovery Conditions

High-temperature exposure: +85℃ / 30 min → Ambient temperature exposure → Low-temperature exposure: -40℃ / 30 min

Maximum Sample Weight: 20 KG

 

 

Structural Features:

 

Standard Configuration of the Test Chamber

Flush-mounted handle.

Door Hinges: Imported SUS #304 stainless steel hinges.

Shelves: Two SUS #304 stainless steel grille-type shelves, with a maximum load of 20KG per layer.

Adjustable Shelf Tracks: Two sets with 40mm adjustable spacing.

Lead-through Port: One φ50mm port at the top of the chamber.

Chamber Door

Single Door: Opens outward, hinges on the left, handle on the right (when facing the front of the chamber).

Equipped with an observation window (W300 x H450mm) made of anti-fog tempered glass and Philips lighting.

Anti-condensation Heating Device: For window and door frames.

Additional Tempered Glass: Allows clear observation of tests inside the chamber.

Control Panel 7-inch display screen, over-temperature protection settings, SD card slot, and RS232 communication interface.
Mechanical Room Refrigeration unit, compressor water tray, and pressure relief device.
Power Distribution Control Cabinet Power distribution board, cooling fan, and main power switch.
Heater

Type: Finned tubular stainless steel electric heater.

Heating Control Method: SSR (Solid State Relay) with zero-crossing

point and periodic pulse width modulation.

Heating Power for Low-Temperature Zone: Approximately 6KW.

Heating Power for High-Temperature Zone: Approximately 9KW.

Power Cable Port and Drain Port Located at the back of the chamber.
Electrical Controller Model Custom seven-inch controller.
Operating Model Programmable operation / Chinese and English menu, touchscreen input.
Setting Range

High-temperature chamber preheating upper limit: +210℃

Low-temperature chamber pre-cooling lower limit: -80℃

Controller Specifications

Accuracy: Temperature ±0.1℃ + 1 digit

Resolution: Temperature ±0.01℃

Temperature slope: 0.1 ~ 9.9 (adjustable).

Includes upper and lower limit standby and alarm functions.

Temperature input signal: T-type armored thermocouple sensor.

6 sets of P.I.D. control parameters with automatic P.I.D. calculation

 

 

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2 0High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2 1

High-Performance Thermal Shock Test Chamber -40℃ To 150℃ Range IEC60068-2 2

 

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2025 Sinuo Testing Equipment Co. , Limited . All Rights Reserved.